TROUBLESHOOTING (CONT.)

Problem

RF input low.

1. Verify RF input power is correct.
2. If all is normal, contact Olson Technology Inc. for

further troubleshooting.

Steps to Take

No optical power at the
optical output port.

1. Clean the connector.
2. Verify laser function is set on.
3. Measure the optical power at the output port using

an optical power meter.

4. If there is no optical power at the output port, the

unit must be returned to the factory for service.
Contact Olson Technology Inc. for more
information.

Optical power is lower than
the required amount.

1. Ensure all connectors are clean.
2. Verify the cable is terminated with the correct

connector type.

3. Measure the optical power at the output port using

an optical power meter.

4. If the optical power is still low, the unit must be

returned to the factory for service. Contact Olson
Technology Inc. for more information.

Typical CNR Performance

Power

Loss

9dB 10dB 11dB 12dB 13dB 14dB 15dB

+8dBm

+10dBm

+12dBm

+13dBm

51

50

53

52

51

50

53

52

51

50

53

52

51

50

7dB

8dB

53

52

Power

Loss

0dB

1dB

6dB

7dB

8dB

+6dBm

+3dBm

4dB

5dB

2dB

3dB

53

52

51

50

53

52

51

50