UNINSTALL THE TRANSMITTER MODULES

ALARM DEFINITIONS

DANGER: Laser Radiation—Avoid direct exposure to beam. Inbound laser radiation
associated with this optical output jumper is generated by a Class IIIb laser product.
Disconnected optical connectors might emit invisible optical radiation. Laser light, visible
or invisible, can seriously injure eyes and even cause blindness.

1

Disconnect the optical fiber s from the rear panel of the transmitter. Immediately
place protective caps over the bulkhead and fiber connector

2

Disconnect the RF cables from the F connectors

3. Loosen the thumbscrew on the front panel of the module CAUTION: Do not pull

on the thumbscrew to remove the module. Pull on the handle that the thumbscrew
goes through to remove the module.

4. Gently pull the module from the chassis using the handle that the thumbscrew

goes through

First push SET on the LED display and set function.

.

( )

.

.

-

.

.

.

Displayed Message

Alarm Status

System Response

No alarm

STA LED is green

Optical output low

STA LED turns to red

Optical output high

Laser bias high

000
001
002
003
004
005
006
007
008

Laser temperature high

RF input low

Module temperature high

TEC current high

RF input high

STA LED turns to red
STA LED turns to red
STA LED turns to red
STA LED turns to red
STA LED turns to red
STA LED turns to red
STA LED turns to red

TROUBLESHOOTING

When the Status light is red the operator can use “

” “

” and “SET” push button

switch to check the alarms. DANGER/CAUTION: Do not remove the cover of the
transmitter or attempt to modify any part of it under any circumstances. Removing the