This can cause RF radiation and ingress problems. The internal cooling is also reduced when
uncovered.

Be sure to replace and tighten all top cover screws. Oscillation or RF radiation can be caused by
loose or missing screws. There is no user adjustable internal laser power adjustment. Any change
to the laser power will result in poorer modulation characteristics and reduced link performance.

EXTERNAL CONTROLS AND TEST POINTS

There are two external DC test points. One reads laser current at 1V per 50mA. A typical laser
current of 30mA would read 0.6V at this test point. The laser power test point is 0.1V per mW.
This is for historical tracking. The optical power meter is a much more accurate means of
measuring power. Both of these test points should be measured with a high impedance voltmeter.

Mount the unit and apply power. The laser is temperature controlled. The unit will operate

INITIAL SETUP

immediately after turn on, but requires about 5 minutes to temperature stabilize. Measure and
record the optical output with a power meter. Measure and record the laser current and optical
power readings at the external test points.