Olson Technology OTLT-87XX-40-SA User Manual
Page 5

FIGURE 1 - OTOT-87XX MOUNTING DIAGRAM
OPTICAL CONNECTORS AND CLEANING
The standard optical connector is an SC/APC. In order to use FC/APC connectors, you must
order a conversion kit, OTLL-SCFCKIT. The standard optical connector location is on the
opposite side from the RF connector.The connector can be moved to the other side by swapping
it with a cover plate. Only a screwdriver is required for this operation.
The fiber ends can be damaged by the insertion of contaminated connectors. Some types of
customer damage to connectors are not covered under warranty. Fiber connectors should never
be left uncovered. Prepackaged alcohol wipes are the most convenient means of cleaning optical
connectors. Clean alcohol and lint free wipes or swabs may also be used.
INTERNAL CONTROLS
There are no internal user adjustments. The only reason to open the unit would be to move the
fiber connector to the other end of the unit. This should be done before the unit is attached to a
rack mount kit. The unit should not be operated for long periods of time without a top cover.
025-000538 REV 1
4/06/09
Page 5