Northern Airborne Technology 806 User Manual
Page 8

806 and 807 Audio Selector Panels
SM806 Installation and Operation Manual
Section 1 Rev: 1.00
Issue 4
Page 1-2
ENG-FORM: 800-0113.DOT
CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.
Input Signals (806 and 807)
NAME TYPE
LABEL
SPECIFICATION
Speaker input
Audio
SPKR INPUT HI
Passive feed through
Normal Microphone
Audio
NORMAL MIC HI
Impedance: 130
Ω -65/+390 Ω
Circuitry: Single ended
Mic bias: 26
±5mA dc
Oxygen Microphone
Audio
OXY MIC HI
Impedance: 130
Ω -65/+390 Ω
Circuitry: Single ended
Mic bias: 26
±5mA dc
Hand Microphone
Audio
HAND MIC HI
Impedance: External
Circuitry: Single ended
Mic bias: External
Aural Warning Bypass
Audio
AW BYPASS IN
1.5 Vrms when AW BYPASS OUT
terminated into 600
Ω
Oxygen Microphone
Interconnect
Control
OXY MIC MODE
INTERCONNECT
Active Low
10 mA maximum
(Yoke) Push to Talk Key
Control
PTT KEY SWITCH
Active Low
10 mA maximum
Normal / Oxygen
Microphone Key
Control NORM/OXY
MIC TIP PTT
Active Low
10 mA maximum
Hand Microphone Key
Control
HAND MIC PTT
Active Low
10 mA maximum
Vox Threshold
Control
VOX THLD
10 mA maximum
Interphones Listen
Control
INPH LISTEN
Active Low
10 mA maximum
Test Mode Jumper In
Control
TEST MODE
JUMPER IN
10 mA maximum
Input Signals (807 only)
NAME TYPE
LABEL
SPECIFICATION
Emergency Switch In
Control
EMER SWITCH IN
28 Vdc, 100 mA maximum