PIA01-001

Environmental Qualification Form

Rev: 1.00

Dec 2, 2009

Page 2 of 3

ENG-FORM: 521-0102.DOT

CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.

Conditions

Section

Description of Conducted Tests

Explosive Atmosphere

9.0

Category X, no test performed.

Waterproofness

10.0

Category X, no test performed.

Fluids Susceptibility

11.0

Category X, no test performed.

Sand and Dust

12.0

Category X, no test performed.

Fungus

13.0

Category X, no test performed.

Salt Fog

14.0

Category X, no test performed.

Magnetic Effect

15.0

Category Z.


Power input


16.0


Category Z.

• The system was tested to DO-160E

subparagraph 16.6.1.3 b, requirement for
equipment with digital circuits.

• The system was tested to DO-160E

subparagraph 16.6.1.1 b (3) Emergency
Operating Voltage conditions.

• The system was tested to DO-160E

subparagraph 16.6.2.2 Low Voltage
Conditions


Voltage Spike


17.0


Category A.


Audio Frequency Susceptibility


18.0


Category Z.

Induced Signal Susceptibility

19.0

Category [ZC].


Radio Frequency Susceptibility


20.0


Category [RR].

Radio Frequency Emission

21.0

Category H.

Lightning Induced Transient
Susceptibility

22.0 Category

[A3J33].

Lightning Direct Effects test

23.0

Category X, no test performed.

Icing