PTA12-300 POTS Telephone Adapter with NVIS Display

SM55-3 Installation and Operation Manual

Section 1 Rev: 1.00

Issue 4

Page 1-4

ENG-FORM: 800-0114.DOT

CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.

Off-hook Condition

Impedance

600 Ohms @ 1kHz (nominal)


Circuitry Type

Balanced


DC Loop Current

25 mA (typical) to 130 mA (max)


DC Voltage

≤9.0 Vdc @ 25 mA loop current


Frequency Response

≤3 dB roll-off from 350 Hz to 3 kHz


Distortion

≤5% THD


Audio Noise

≤ -50 dB from rated output (no signal)


Available Audio

TX Audio, RX Audio


TX Audio

-1 dBm

±1dB into 600 Ohms with <5% THD

(Mic Input to tip/ring)

(test condition: 250 mVrms @ 1kHz into Mic input, Mic level
potentiometer set to max.)


RX Audio

-20 to 0 dBm

(Typ expected

400 mVrms @ 1kHz RX audio on TIP/RING yields rated phones

audio level)

output with both front panel VOL control and RX level
potentiometer set to max.


DTMF Signaling

Standard DTMF frequencies used


Frequency Tolerance

±1.5%


Supported Codes

0 – 9, *, #


DTMF TX on tip/ring

-2.2 dBm

±1.0 dB into 600 Ohms (DTMF level potentiometer set

to max.)

Serial Port

RS232 protocol, RX, TX and GND

Baud Rate

19200


Frame Size

8 bits


Parity none

Stop Bits

1


Flow Control

Not available