Power on checks

a)

Power up the ship's systems with the RS08 installed, and check that the mode
annunciators transfer correctly with the appropriate switch selection. If the ‘ILS
Interlock’ is used in the installation, check that selecting the primary NAV system
to an ILS channel returns the display to the NAV/ILS mode, regardless of switch
setting.

b)

Depending on the method selected for lamp dimming, ensure that operation
iscorrect (dimmer pot or switch) and that both lamps are fully functional. The
system cannot be accepted for service until all annunciations are correct.

c)

Using a ramp test set or locally broadcast navigation signal, ensure that valid data
is presented on the shared indicator when in the primary NAV mode. To check,
turn off the secondary NAV receiver, and ensure that there is no interaction, or
cross-connected wiring. Switch the RS08 to the secondary NAV mode, and using
a ramp test set or locally broadcast navigation signal, ensure that the correct
presentation is provided on the shared indicator. To double check, rechannel or
turn off the primary NAV receiver, and ensure that there is no interaction or cross-
connected wiring.

2.4 Installation

Drawings

DRAWING REV.

DESCRIPTION

TYPE


RS08\001\302-0

1.01

Remote switch - Standard Configuration

Block Diagram

RS08\001\403-0

1.03

Remote switch - Standard Configuration

Interconnect

RS08\001\403-1

1.03

Remote switch - Installation Options

Interconnect

RS08\001\403-2

1.03

Remote switch - Master/Slave Configuration

Interconnect

RS08\001\405-0

1.01

Remote switch

Connector Map

RS08\001\521-0

1.00

Remote switch

Environmental Qual Form

RS08\001\903-0 1.03

Remote

switch

Isometric

RS08\001\922-0 1.02

Remote

switch

Mechanical

Section 2.0 ends after these Drawings