4 installation drawings, Rs08\001 – Northern Airborne Technology RS08 User Manual
Page 15
SM15 Rev.4.00
RS08 Remote Switch Manual
Nov 24, 2003
Page 2-3
ENG-FORM: 805-0104.DOT
Amendment #1
Jan 18, 2005
CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.
2.3.4.2
Power on checks
a)
Power up the ship's systems with the RS08 installed, and check that the mode
annunciators transfer correctly with the appropriate switch selection. If the ‘ILS
Interlock’ is used in the installation, check that selecting the primary NAV system
to an ILS channel returns the display to the NAV/ILS mode, regardless of switch
setting.
b)
Depending on the method selected for lamp dimming, ensure that operation
iscorrect (dimmer pot or switch) and that both lamps are fully functional. The
system cannot be accepted for service until all annunciations are correct.
c)
Using a ramp test set or locally broadcast navigation signal, ensure that valid data
is presented on the shared indicator when in the primary NAV mode. To check,
turn off the secondary NAV receiver, and ensure that there is no interaction, or
cross-connected wiring. Switch the RS08 to the secondary NAV mode, and using
a ramp test set or locally broadcast navigation signal, ensure that the correct
presentation is provided on the shared indicator. To double check, rechannel or
turn off the primary NAV receiver, and ensure that there is no interaction or cross-
connected wiring.
2.4 Installation
Drawings
DRAWING REV.
DESCRIPTION
TYPE
RS08\001\302-0
1.01
Remote switch - Standard Configuration
Block Diagram
RS08\001\403-0
1.03
Remote switch - Standard Configuration
Interconnect
RS08\001\403-1
1.03
Remote switch - Installation Options
Interconnect
RS08\001\403-2
1.03
Remote switch - Master/Slave Configuration
Interconnect
RS08\001\405-0
1.01
Remote switch
Connector Map
RS08\001\521-0
1.00
Remote switch
Environmental Qual Form
RS08\001\903-0 1.03
Remote
switch
Isometric
RS08\001\922-0 1.02
Remote
switch
Mechanical
Section 2.0 ends after these Drawings