1.4.3 Environmental
Specifications
Temperature
-40 to +70
°C (Ambient)
Altitude
RS08-001
25,000
ft.
max.
RS08-350
35,000
ft.
max.
RS08-500
50,000
ft.
max.
Humidity
95%
Non-Condensing
Shock
6g (all axes)
DO-160B Env. Cat:
RS08-001
/A1B1/BA/MNO/XXXXXXABBBBBB
RS08-350
/A1C1/BA/MNO/XXXXXXABBBBBB
RS08-500
/A1D1/BA/MNO/XXXXXXABBBBBB
1.5
Unit
Nomenclature
The following list indicates the models available at the date of publication of this
document. Other models may be available.
Model
Description / Distinction
RS08-001
Remote
switch
Interlock and lamp dimmer (2 step)
Provides 6 poles of data transfer
Provides 2 poles of lamp transfer
14/28 Vdc operation
Gold contacts, sealed 50 g relays
Includes flag bias generator
Automatic ILS reversion circuit
Easily cascaded for more complex installations
RS08-350
Identical to RS08-001 but qualified to 35,000 feet
Suitable for mounting in unpressurized areas
RS08-500
Identical to RS08-001 but qualified to 50,000 feet
Suitable for mounting in unpressurized areas
End of Section 1.0