1 4 specifications, 1 electrical specifications, 2 physical specifications – Northern Airborne Technology RS08 User Manual
Page 10
RS08 Remote Switch Manual
SM15 Rev.4.00
Page 1-2
Nov 24, 2003
ENG-FORM: 800-0106.DOT
CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.
1.4 Specifications
1.4.1 Electrical
Specifications
Input Power
+9 to 33 Vdc at 100 mA Max. (Excluding lamps).
Case is internally grounded.
Lamps
Type 327/387 for 28 V (40 mA).
Type 330/382 for 14 V (80 mA).
Maximum lamp load is 100 mA if internal dimming
function
is
used.
Logic
Ground seeking input for switch transfer.
Ground seeking ILS Enable input to return indicator to
ILS mode. Will accept positive bias on this line from
5-12 V, and an external diode or transistor junction in
series with the ground return.
Indicator
Dry circuit switching to accommodate standard HSI
levels (500
µA), or up to 2 A @ 28 Vdc.
Flag bias
1.0 mA, if required.
Loads
External 1 K
Ω, if required.
Annunciators
Lamp circuitry provided for mode annunciation.
Optional remote switch selectable dimming for 14/28V.
1.4.2 Physical
Specifications
Height
1.25 inches (31.75 mm)
Depth
2.30 inches (58.42 mm) (excluding connector)
Width
4.50 inches (114.30 mm)
Mounting
Bulkhead attachment (4 x 1032/AN3)
Weight
6 oz. (168 g) (excluding mating connector)