① Serial Communication setting
You can set up serial communication
parameters. (Usable serial port number, baud
rate: 57600)
② UDP Communication setting
You can set up UDP communication
parameters. IP text box : BUC IP
TX : BUC UDP(Ethernet) Port
RX : Master UDP(Ethernet)
port
③ Gain setting
This button is used to change the gain of the BUC.
④ SSPA On function
This button is used to turn on the SSPA of the BUC.
⑤ SSPA Off function (Mute)
This button is used to turn off the SSPA of the BUC.
⑥ UDP Command
This text box is used to control the BUC with commands via UDP (Ethernet) communication. If
you click command list button(
⑨), You can see the command list. (Refer to the serial
Commands list in
5.2.2)
⑦ Serial Command
This text box is used to control the BUC with commands via serial communication. If you click
command list button(
⑨), You can see the command list. (Refer to the serial Commands list in
5.2.2)
⑧ DebugMode
This button is used to debug the BUC. It’s not used for operation.
⑨ Command List
This button shows the command list. (Refer to the serial Commands list in 5.2.2)
⑩ BUC Monitoring
This window shows the current status of BUC output power, temperature, LO lock status, over
temperature, over RF power, external mute.
⑪ Status display window
This window shows the command processing result
⑫ Clear
This button is used to clear status display window
⑬ Firmware Version Display
Firmware major version number must match that of GUI. For example if the firmware version
is 2.X, GUI program version should be 2.X.
⑭ GUI Program Version Display.
.