Norsat O3b 10W BUC User Manual
Page 17
© 2013 Norsat International Inc.
Page 17 of 26
o
SSPA On function
o
This button is used to turn on the SSPA of the BUC.
o
SSPA Off function (Mute)
o
This button is used to turn off the SSPA of the BUC.
o
Gain setting
o
This button is used to change the gain of the BUC
o
Serial Command
o
This text box is used to control the BUC with commands via serial communication. If you
click command list button(⑦), You can see the command list. (Refer to the serial Commands
list in 5.1.4)
o
UDP Command
o
This text box is used to control the BUC with commands via UDP (Ethernet) communication.
If you click command list button(⑦), You can see the command list. (Refer to the serial
Commands list in 5.1.4)
o
DebugMode
o
This button is used to debug the BUC. It’s not used for operation.
o
Command List
o
This button shows the command list. (Refer to the serial Commands list in 5.1.4)
o
Clear
o
This button is used to clear status display window
o
BUC Monitoring
o
This window shows the current status of BUC output power, LO lock status, temperature,
over temperature, over RF power, external mute.
o
Serial Communication setting
o
You can set up serial communication parameters.
o
(Usable serial port number, baud rate: 57600)
o
UDP Communication setting
o
You can set up UDP communication parameters.
o
IP text box : BUC IP
o
TX : BUC UDP(Ethernet) Port
o
RX : Master UDP(Ethernet) port
o
Status display window
o
This window shows the command processing result.
Serial Commands List
5.2.2
Table 2. Serial Commands List
Item
Command
Example
Explanation
1
gst
gst
Get BUC status
2
sspaon
sspaon
Turn on SSPA
3
sspaoff
sspaoff
Turn off SSPA
4
sendipwr
sendipwr 192 168 100 2
Write master(PC) ip
5
sendiprd
sendiprd
Read master ip
6
sendportwr
Sendportwr 4001
Write master port
7
sendportrd
sendportrd
Read master port
8
ipwr
ipwr 192 168 100 10
Write BUC ip