2 specifications, 1 mechanics, 2 power supply – Nevion SD3232M User Manual
Page 6: 3 control

Modular 3G SD Video Rev. E
nevion.com | 6
2 Specifications
2.1 Mechanics
Dimensions:
HxWxD = 396x483x340mm, (19”, 9RU), or
HxWxD = 220x483x340mm, (19”, 5RU).
Frame weights:
FR-6464-MR-3GHD (5RU): 9.8kg,
FR-128128-MR-3GHD (9RU): 16.0kg,
Weights above include standard equipment according to
Price List item specification.
Router weights:
3GHD6464S / SD6464S (5RU): 12.3kg
3GHD128128M / SD128128M (9RU): 21.0kg
Weight of fully populated router frame.
Backplane card:
128x128 (9RU), or
64x64 (5RU).
X-point Modules:
32x32 module cards.
System Controller:
1 Multicon
2
card required, 1 redundant card is optional.
2.1.1 Emission/Immunity and Safety standards
Emission/Immunity standards: Compliant with CE EN55103-1 and 2, FCC part 15.
Safety standards:
Compliant with CE EN60950, UL-1950/CSA22.2.
2.2 Power supply
Built-in, redundant power supply. 1 module included, 1 (redundant) optional.
Total power consumption:
<300W.
AC Supply voltage range:
90-130VAC / 180-254VAC, switchable, 50-60Hz, 300W.
AC Mains connector:
IEC 320, separate input for each PSU module.
Optional DC/DC power supply:
DC Supply voltage range:
36 - 72VDC, 300W.
DC Mains connector:
Screw terminal, separate input for each PSU module.
Alarms:
Power failure alarm on relay contact closure, LED in front,
and Open Collector.
Alarms connector:
RJ45.
2.3 Control
Standard features:
Serial ports:
Connector:
RS-232/RS-422 for protocol conversion, to VikinX compact
control protocol, or to third party protocols. (1x per Multicon2
card);
DB9, female.
Ethernet ports:
Connector:
10/100BaseT Ethernet bus for external router control with
new protocol. (1x per Multicon2 card).
RJ45.
EDH & Monitoring:
Connector:
Error Detection and Handling integrated in monitoring
outputs.
1 channel available for switch through inputs.
BNC.
Monitored parameters:
(via Multicon2)
-
Loss of signal.
-
Lock and clock rate on reclockers.
-
Module temperature.
-
Internal module voltages.
2
Syscon may be applied instead of Multicon VX-MOD in the router until further notice.