beautypg.com

4 led status indication, 1 start-up, 2 alarm states – Nevion Sublime Control Panels User Manual

Page 12: 3 ethernet states, 4led status indication

background image

VikinX Sublime Control Panels

Rev. M


nevion.com | 12

4

LED status indication

4.1 Start-up

The LED located at the front of the control panel indicates the status of the panel. At start-
up, the LED will alternate between red (R) and green (G) every 500ms for about two
seconds. After the start-up sequence the LED will indicate the Alarm state of the panel.

There are two LEDs located at the Ethernet bus. At start-up the boot loader is searching for
update commands on the serial port for about two seconds. During this sequence both
Ethernet LEDs will be blinking. After the start-up sequence the LEDs will indicate the
Ethernet state.

4.2 Alarm states

The LED can either be red (R), green (G), yellow (Y) or have no light (N).

The LED state is here described with twenty letters, each representing 100ms, which totals
to an alarm sequence of two seconds. The X indicates that the LED keeps the color it has
the moment the alarm sequence begins (green, yellow or no light).

Description

LED state

Alarm

Comment

Continuous
green light

GGGGG GGGGG GGGGG
GGGGG

No alarm.
Status is OK.

Continuous
yellow light

YYYYY YYYYY YYYYY YYYYY

Unable to
connect to
controller
over
Ethernet.

This alarm will be
overwritten by other
alarms

Long red
blinks

RRRRR NNNNN RRRRR
NNNNN

Power is too
low.

One short
red blink

RXXXX XXXXX XXXXX XXXXX

Power A
failed

Only active if power
alarm dip is set.

Two short
red blinks

XXXXX XXXXX RXRXX XXXXX

Power B
failed

Only active if power
alarm dip is set.

Red with one
short yellow
blink

YRRRR RRRRR RRRRR
RRRRR

No valid
product key.

4.3 Ethernet states

The LEDs that are located at the Ethernet bus will after the Start-up sequence indicate the
Ethernet states:

On

Off / Blinking

Green

Valid link

No link

Yellow

No data

Data is transmitted or received