4 external power alarm, 5 power-up mode – Nevion SL-3GHD128128-RC User Manual
Page 14

SL-3GHD128128-RC
Rev. A
nevion.com | 14
3
87
3
87
…
…
…
…
42
126
42
126
In-/Outputs 127 and 128 are not in use in this router setup (3 layers).
4 layers:
Layer 1
Input
Layer 1
Output
1
1
1
1
2
2
2
2
…
…
…
…
32
32
32
32
Layer 2
Input
Layer 2
Output
1
33
1
33
2
34
2
34
…
…
…
…
32
64
32
64
Layer 3
Input
Layer 3
Output
1
65
1
65
2
66
2
66
…
…
…
…
32
96
32
96
Layer 4
Input
Layer 4
Output
1
97
1
97
2
98
2
98
…
…
…
…
32
128
32
128
3.4 External power alarm
The external power alarm can be switched according to the following pattern:
SW 7
Power alarm
OFF
Disables External Power Alarm
ON
Enables External Power Alarm
Default setting is External Power Alarm disabled.
3.5 Power-up mode
Switch 8 on the configuration switch defines the power up mode. The sublime router
provides two modes for powering up the system.
The power up options can be switched according to the following pattern:
SW 8
Power Up mode
OFF
Switches all outputs according to the buffered
information in the routers processor system.
ON
Switches all outputs to input 1.
Default setting switches all outputs according to the buffered information in the routers
processor system.