3 configuration, 1 power supply setup, 2 router level – Nevion SL-3GHD128128-RC User Manual
Page 12: 3configuration

SL-3GHD128128-RC
Rev. A
nevion.com | 12
3
Configuration
This chapter provides an overview of the configuration options that are available on the
SL-3GHD128128-RC router.
Some of the configuration options demand software configuration, using the Nevion
Configurator. This tool is supplied with each router, but can also be downloaded from our
web sit
It is important that users apply Nevion Configurator v4.1.1 (or a higher version
number) when configuring the SL-3GHD128128-RC and its variants.
3.1 Power Supply setup
Before proceeding with router configuration, make sure the accompanying power supply
unit is configured for the right AC supply voltage.
There is a switch on the rear side of the power supply module that selects mains voltage.
The mains voltage can be either 110VAC or 230VAC.
This switch must be set in the correct position, depending on the mains voltage on the
router’s site.
Failing to select correct AC mains voltage properly may damage the Power
Supply Unit.
3.2 Router level
Switches 1 -
4 on the configuration switch set the router’s level for communication with the
Router Management System and other units in the NCB system. The panels on the NCB
dedicated to operate with the router must be configured to the same level as that router.
If several routers are combined to form an Audio Follow Video, RGB or similar system,
these routers must be configured to the same level.
The levels can be switched according to the following pattern:
SW 1
SW 2
SW 3
SW 4
Level
NCB Address
OFF
OFF
OFF
OFF
1
0
OFF
OFF
OFF
ON
2
1
OFF
OFF
ON
OFF
3
2
OFF
OFF
ON
ON
4
3
OFF
ON
OFF
OFF
5
4
OFF
ON
OFF
ON
6
5
OFF
ON
ON
OFF
7
6
OFF
ON
ON
ON
8
7
ON
OFF
OFF
OFF
9
8
ON
OFF
OFF
ON
10
9
ON
OFF
ON
OFF
11
10
ON
OFF
ON
ON
12
11
ON
ON
OFF
OFF
13
12
ON
ON
OFF
ON
14
13
ON
ON
ON
OFF
15
14
ON
ON
ON
ON
16
15
Default level is 1.