Module status

The status of the module can be monitored in three ways.

1. Multicon Gyda System Controller (optional).

2. GPI at the rear of the sub-rack.

3. LED’s at the front of the sub-rack.

Of these three, the GPI and

the LED’s are mounted on the module itself, whereas the GYDA

System Controller is a separate module giving detailed information on the card status.

6.1 Multicon Gyda

6.2 GPI ALARM

– Module Status Outputs

These outputs can be used for wiring up alarms for third party control systems. The GPI
outputs are open collector outputs, sinking to ground when an alarm is triggered. The GPI
connector is shown in figures below.

Electrical Maximums for GPI outputs

Max current : 100mA

Max voltage : 30V

6.2.1 GPI connections

DVI-SDI-2 module GPI pinning:

Signal

Name

Pin # Mode

Status

General error status for the module. Pin 1 Open Collector

LOS1

Loss of signal or missing SFP on
channel 1.

Pin 2 Open Collector

LOS2

Loss of signal or missing SFP on
channel 2.

Pin 3 Open Collector

Ground

0V / gnd pin.

Pin 8 0V.