2 front panel - status monitoring – Nevion HDSDI-CHO-2x1 User Manual
Page 10
HDSDI-CHO-2x1
Rev. G
nevion.com | 10
5.2 Front panel - Status monitoring
The status of the module can be easily monitored visually by the LED’s at the front of the
module. The LED’s are visible through the front panel as shown in the figure below.
Figure 8: indicator overview for HDSDI-CHO-2x1;
(Text not printed on the front panel)
The HDSDI-CHO-
2x1 has 4 LED’s each showing a status corresponding to the GPI pinning.
The position of the different LED’s is shown in the figure above.
Diode \ state
Red LED
Yellow LED
Green LED
No light
Status
Module is faulty
Module is OK;
Module power is
OK
Module has no
power
Lock&LOS
Loss Of Signal &
No Reclocker
lock
Signal present &
No Reclocker
lock
Signal present &
Reclocker in lock
Input 1
No input signal
on Input 1
Signal present &
not selected
Signal present &
Input 1 selected
Input 2
No input signal
on Input 2
Signal present &
not selected
Signal present &
Input 2 selected