6 configuration by dip, 6configuration by dip – Nevion 3GHD-CHO-2x4 User Manual
Page 9

3GHD-CHO-2x4/2x3
Rev. C
nevion.com | 9
6
Configuration by DIP
The 3GHD-CHO-2x4 supports a number of different formats. The correct configuration can
either be set with a DIP switch or with the GYDA system controller. The layout of 3GHD-CHO-
2x4 is shown in the drawing below.
Figure 3. 3GHD-CHO-2x4 module layout
DIP switch configuration must be set according to the table below:
Switch # Label
Function DIP=OFF
Function DIP=ON
Comment
1
CHO Distribution functionality
Change-over
functionality
Card functionality
2
IN1
Input 1 standby, 2 main
Input 1 main, 2
standby
Select main/standby
for CHO and DA
3
S/D
Single 1x8 (1x6 with
GPI) from main
Dual 1x4 (1x3 with
GPI)
With CHO, dual mode
gives CHO +
distributed standby
signal
4
RUL
Loss of signal
Loss of lock
Signal integrity
decision in change-
over mode.
N/A in distribution
mode.
5
LTC
Non-latching switch. Will
automatically return to
main when input signal is
”good”
Latching switch. Must
be reset to return
from standby to main
“Sticky” switching
”good” is depending on
switch criteria in
change-over mode.
N/A in distribution
mode.
6
RCL
Reclocker Bypass
Reclocker ON
Reclocker mode
7
EQ
Cable equalizer Bypass
(Loss of signal will not
work on this mode)
Cable Equalizer ON
Equalizer mode
8
OVR Module controlled by
Gyda system controller
Module controlled by
DIP switches
Select GYDA config.
mode
Table 4: 3GHD-CHO DIP switches
All DIP switches are off when pointing towards the release handle.
DIP switches