Connections, 1connections – Nevion HD-TD-10GX-8-SFP User Manual
Page 5
HD-TD-10GX-8
Rev. A
nevion.com | 5
1
Connections
The backplane HD-TD-10G-C1 is used for the HD-TD-10GX-8-SFP module. All external
connections are made via the backplane.
The backplane occupies two slots in the Flashlink frame, and the module will then go in the
rightmost of the two slots.
Function
Label
Connector type
HD/SD-SDI channel 1
Ch1
BNC input
HD/SD-SDI channel 2
Ch2
BNC input
HD/SD-SDI channel 3
Ch3
BNC output
HD/SD-SDI channel 4
Ch4
BNC output
HD/SD-SDI channel 5
Ch5
BNC bidirectional
HD/SD-SDI channel 6
Ch6
BNC bidirectional
HD/SD-SDI channel 7
Ch7
BNC bidirectional
HD/SD-SDI channel 8
Ch8
BNC bidirectional
TX optical port w/cover
OPT1
SC/UPC
RX optical port w/cover
OPT2
SC/UPC
GPI outputs
GPIO
TP45, pin 2 (card status, open when
alarm)
TP45, pin 3 (optical alarm),
TP45, pin 6 (channel 1-8 status,
closed when alarm)
GPI inputs
GPIO
TP45, pin 1 (laser disable, active low)
GPI GND
GPIO
TP45, pin 8
---
Ethernet TP45
Table 1: Connector functions
Illustration 1: The backplane, HD-TD-10G-C1