2 multicon gyda override, 3 default configuration, 4 6.5 in-band management – Nevion ETH1000-SW-COM User Manual
Page 13: Multicon, Group, Table 6.2, 3 default configuration, 4 group of cards

Configuration
13
ETH1000-SW-COM Manual Rev. B
6.2 Multicon GYDA override
Switch 1 is used to control if Multicon GYDA is used for configuration or if it is done using DIP
switches only. When activated (ON) switch 3 to 7 will be used. These switches will be ignored
when configured with GYDA.
It is possible to have up to eight cards on the same LAN in this mode. Each card will get a fixed
IP address, see
. Two and two cards will be paired making a “link” between the ports on
the back, P1 to P1, P2 to P2 and so on. Card 1 and card 2 will be paired, card 3 and card 4 will be
paired, and so on.
The serial ports will be configured as RS422, 115200 baud rate, 8 bits of data, no parity bit and one
stop bit.
Table 6.2 Local IP configuration when in Multicon GYDA over-
ride mode
SW7 SW6 SW5 Position in
card group
Local IP configuration
Address
Netmask
Gateway
0
0
0 Card 1
192.168.1.1 255.255.255.0 192.168.1.254
0
0
1 Card 2
192.168.1.2 255.255.255.0 192.168.1.254
0
1
0 Card 3
192.168.1.3 255.255.255.0 192.168.1.254
0
1
1 Card 4
192.168.1.4 255.255.255.0 192.168.1.254
1
0
0 Card 5
192.168.1.5 255.255.255.0 192.168.1.254
1
0
1 Card 6
192.168.1.6 255.255.255.0 192.168.1.254
1
1
0 Card 7
192.168.1.7 255.255.255.0 192.168.1.254
1
1
1 Card 8
192.168.1.8 255.255.255.0 192.168.1.254
6.3 Default configuration
Default local IP configuration is:
Address: 192.168.1.1
Netmask: 255.255.255.0
Gateway: 192.168.1.254
6.4 Group of cards
For ETH1000-SW-COM to create IP connections it must know the IP address of the other cards.
A list of up to eight cards can be configured, including its own local IP address. These cards will
form a group of cards. It is recommended that this group has the same order on all cards. This
will make it easier when using the different matrices.