beautypg.com

3 front panel, Status monitoring – Nevion WOS-2 User Manual

Page 11

background image

WOS-2

Rev. H


nevion.com | 11

Max output current: 100mA

Max output voltage: 30V

WOS-2x1/WOS-2x2 GPI pinning:

Signal

Name

Pin #

Input/Output

Mode

Status

General error status for the module

Pin 1

Output

Open Collector

Standby Alarm when switch in standby mode

Pin 2

Output

Open Collector

Switch to standby mode

Pin 5

Input

0V= standby
5V= main

Reset switch to main position

Pin 6

Input

Reset switch to main position

Pin 7

Input

Ground

0 volt pin

Pin 8

0V

The switch is set in standby mode by sinking pin5 to ground. Pin6 and pin7 are hardwired as
logical OR and when either is sunk to ground, they will reset the latching switch to main
position. Resetting can also be done with GYDA system controller

Figure 10: GPI Outlet

5.1.3 Front Panel

– Status Monitoring

The status of the module can be easily monitored visually by the LEDs at the front of the
module. The LEDs are visible through the front panel as shown in Figure 9

Figure 11: Diode overview of WOS-2x1(L)/WOS-2x2(L)

Both WOS-2x1(L) and WOS-2x2(L) have 2 LEDs each showing a status corresponding to
the GPI outputs.

Diode \ state

Red LED

Green LED

No light

Status

Module is faulty

Module is OK
Module power is OK

Module has no power

Main/standby

Switch in standby position

Switch in main position