Logs, Ncast presentation recorder reference manual – NCast PR720 User Manual
Page 38
NCast Presentation Recorder Reference Manual
There are two methods by which to choose a notification to be reported:
•
Select by event type – Any event which is assigned the selected severity level is reported. Selecting
“Info” will report Info level events, but not others. You must also select “Critical” and “Error” to be
informed about events classified as Critical and Error.
•
Select by event name – Any activity identified by the given name is reported. It does not matter if the
“type” box is checked or not, the report is issued.
So a typical strategy for using this selection page is as follows:
First, select the severity level desired for reporting. Typically this would be “Critical” and “Error” unless there
is an interest in the more frequent and less interesting “Warning” and “Info” messages.
Next, select particular events of interest to be reported. Perhaps “Session start” and “Recording start” are
required. The net result is that all “Critical” and “Error” messages will be generated, and “Info” level
messages about “Session start” and “Recording start” will be sent as well.
3.10. L
OGS
Several run-time logs are maintained by the Presentation Recorder and are accessed via the Logs page:
3.10.1.View Event Logs
Many events during the operation of the Presentation Recorder are recorded in the Event Logs. These Logs
are part of the Event Notification System discussed in Section 3.9.
NCast Corporation
Revision 1.1
Page 38