Chapter 3 functional diagram, Chapter 4 specifications, 1 link test condition – MultiDyne CTV-2000-FTX Series User Manual
Page 6: 2 specifications table
CTV2000-FTX Series CATV Fiber Optic Transmitter Users’ Manual
6
Chapter 3 Functional Diagram
RF INPUT
Digital
Attenuator
Pre-Amplifier
Power Amplifier
RF Test
Predistortion
Board
DFB Laser
Optical Output
ATC
APC
MicroProcessor
VFD Display
Power Supply
AC INPUT
Network
Management
AGC/MGC
-20dB Test
Chapter 4 Specifications
4.1
Link Test Condition
The following test link consists of the CTV2000-FTX transmitter, 10Km standard fiber, an optical
attenuator and standard optical receiver. Input RF channels are 77 NTSC channels. Specifications are with
–1dBm optical input power to an optical receiver.
4.2 Specifications Table
Item
Unit
Parameter
Optical Output Power
mW
4
6
8
10
12
14
16
18
20
22
Optical Link Path Loss
dB
7
9
10
11
11.8
12.5
13
13.6
14
14.4
Optical Wavelength
nm
1310±20
Type of Laser
Cooled DFB in 14 pin butter-fly package with isolator
Optical modulation
Direct Modulation
Optical connector Type
SC/APC, Single Mode
Frequency Range
MHz
45~870/1000
RF Input Level
dBmV
15~25
Flatness In Band
dB
±0.75
RF Input Impedance
Ω
75
RF Return Loss
dB
≥16
(45~870)MHz
C/CTB
dB
≥67
C/CSO
dB
≥62
C/N
dB
≥51
AGC Control Range
dB
±5
Power Voltage
V
AC 90V~250V (50/60 Hz)
Power Consumption
W
20
Operation Temperature
℃
0~45
Store Temperature
℃
-20~65
Relative Humidity
%
Max 95% non-condensing
Dimension
mm
433(L) × 325(W) × 44(H)