beautypg.com

Chapter 3 functional diagram, Chapter 4 specifications, 1 link test condition – MultiDyne CTV-2000-FTX Series User Manual

Page 6: 2 specifications table

background image

CTV2000-FTX Series CATV Fiber Optic Transmitter Users’ Manual

6

Chapter 3 Functional Diagram

RF INPUT

Digital

Attenuator

Pre-Amplifier

Power Amplifier

RF Test

Predistortion

Board

DFB Laser

Optical Output

ATC

APC

MicroProcessor

VFD Display

Power Supply

AC INPUT

Network

Management

AGC/MGC

-20dB Test

Chapter 4 Specifications

4.1

Link Test Condition

The following test link consists of the CTV2000-FTX transmitter, 10Km standard fiber, an optical

attenuator and standard optical receiver. Input RF channels are 77 NTSC channels. Specifications are with

–1dBm optical input power to an optical receiver.

4.2 Specifications Table

Item

Unit

Parameter

Optical Output Power

mW

4

6

8

10

12

14

16

18

20

22

Optical Link Path Loss

dB

7

9

10

11

11.8

12.5

13

13.6

14

14.4

Optical Wavelength

nm

1310±20

Type of Laser

Cooled DFB in 14 pin butter-fly package with isolator

Optical modulation

Direct Modulation

Optical connector Type

SC/APC, Single Mode

Frequency Range

MHz

45~870/1000

RF Input Level

dBmV

15~25

Flatness In Band

dB

±0.75

RF Input Impedance

Ω

75

RF Return Loss

dB

≥16

(45~870)MHz

C/CTB

dB

≥67

C/CSO

dB

≥62

C/N

dB

≥51

AGC Control Range

dB

±5

Power Voltage

V

AC 90V~250V (50/60 Hz)

Power Consumption

W

20

Operation Temperature

0~45

Store Temperature

-20~65

Relative Humidity

%

Max 95% non-condensing

Dimension

mm

433(L) × 325(W) × 44(H)