3 transformer, Transformer – MovinCool Office Pro 63 Service Manual User Manual
Page 22

Operation Section
22
6.3 Transformer
• A dry-type transformer rated 5 KVA is equipped
within the unit to provide step down voltage
from 460 V single phase to 230 V single phase.
• The terminal connection of the primary side of
the transformer are labeled H1, H2, H3, and
H4. Terminals H2 and H3 are shorted together
to provide a series connection for 460 V
application. Terminals H1 and H4 are
connected to 460 V power source to supply
power to secondary side.
• Terminals X2 and X3 of the secondary side are
also shorted together to provide 230 V output
between terminals X4 and X1.
Specifications:
Distribution transformer
- Type: Dry type
- Rated VA: 5000 VA
- Power Requirement: 1 PH, 60 Hz
- Primary Voltage: 460 V
- Secondary voltage: 230 V
I001954
Primary
(460 V)
Coil
Secondary
(230 V)
Short Circuit
Short Circuit
H3 H2
H4
X1
X2 X3
X4
H1
Terminal Block
(Secondary)
Terminal Block
(Primary)