Cobra Gold Owner's Manual - Page 3

Section A

Installation

Technical Specifications

Wire Capacity

.023inch - .045inch (0.8mm - 1.2mm) solid and hard wire
.030inch - 1/16inch (0.8mm - 1.6mm) aluminum and cored wire

Wire Speed

800 IPM (20mpm) Max. at rated feeder Input Voltage (120VAC / 42VAC)

Duty Cycle

Air Cooled Torches (211 series) ......................................... 200 amps @50%
Air Cooled Torches (Finned Copper Cup) ........................ 200 amps @100%
Air Cooled Torches (Heavy Duty Finned Copper Cup) .... 225 amps @100%
Water Cooled Torches (210 series) .................................... 250 amps @50%
Water Cooled Torches (Finned Copper Cup) ................... 225 amps @100%
Water Cooled Torches

(Heavy Duty Finned Copper Cup) ...................................... 250 amps @100%
Water Cooled Torches

with Optional Heavy Duty Finned Gas Cup ...................... 300 amps @50%
All ratings are at 25 volts max. using Argon Gas

Shipping Weight (approximate)

Air Cooled

15ft. (4.5m) ....................................... 13 lbs.

(5.9 Kg)

25ft. (7.6m) ....................................... 18 lbs.

(8.2 Kg)

50ft. (15.2m) ..................................... 33 lbs. (14.96 Kg)

Water Cooled

15ft. (4.5m) ....................................... 14 lbs.

(6.35 Kg)

25ft. (7.6m) ....................................... 20 lbs.

(9.07 Kg)

50ft. (15.2m) ..................................... 35 lbs. (15.88 Kg)

Support Equipment Required

C.V. or C.C. Power Source of sufficient capacity for your needs.

Regulated gas supply and hoses.

Properly sized power leads from power source to wire feeder and ground.

Water source and hose capable of providing a minimum of

1 quart

(.95 liter) / min. at 35 p.s.i. when using water cooled torches.

Coolant Recommendations

Use a name-brand additive, which does not contain reactive sulphur or

chlorine and does not react with copper, brass or aluminum.

Use 3 Quarts (2.85 Liters) Distilled water.
Use 1 Quart (.95 Liters) ethylene glycol.
Use 1 tsp (5 ml) liquid glycerin

The Coolant rate should be 1 quart (.95 liter) / minute at 35 p.s.i.