beautypg.com

About the water softener system – Diamond Power Products GXSF27B User Manual

Page 16

background image

About the water softener system.

16

Service: Timer/Softener, Service Checkout Procedure

If you are not getting soft water, and an error code is not displayed, use the procedures below to find the
problem. First make the following visual checks.

VISUAL CHECKS:

Is there electrical power to the outlet the water softening system transformer is plugged
into?
Is there sufficient salt in the storage tank? The tank should be at least 1/3 to 1/2 full of salt.

Is the softener bypass valve directing water for soft water service?

Is the valve drain hose open to the drain, not more than 8

above the softener, and

unobstructed?

If you do not find a problem with the visual checks, continue below.

4

3

2

1

ERROR CODE DISPLAYED ERR 01

ERR 02

ERR 03

ERR 04

ERR 05

POSSIBLE DEFECT

• motor

• position

• motor

• position

• control

inoperative

switch

inoperative

switch or

(PWA)

or wiring

wiring

harness

harness

• wiring harness

• control

• control

• control

or connection

(PWA)

(PWA)

(PWA)

to switch

• position switch

• control (PWA)

Service: Electronic Demand Time Features and Service

To remove an error code: (1) Unplug transformer.

(2) Correct defect.
(3) Plug transformer in.
(4) Wait for at least 6 minutes. The error code will return if the reason

for the error code was not corrected.

NO SOFT

WATER

CONTROL SHOWS
WRONG TIME AND DAY,
AND/OR IS FLASHING.

CONTROL
DISPLAY
BLANK.

CONTROL DISPLAY SHOWS
CORRECT TIME AND DAY
AND IS STEADY.

Check electrical
power to control
(outlet, transformer,
power cable, all
connections).

Do manual

diagnostics.

NO POWER

POWER OK

REPAIR AS
NEEDED

CONTROL
DEFECTIVE

Do manual
diagnostics to
verify proper
function.

Electrical power was off.
Reset the correct time of
day.

Investigate reason for
power loss.

This manual is related to the following products: