beautypg.com

MK Products CobraCooler 2005 User Manual

Page 9

background image

Owner’s Manual - Page 8

Section 1 TECHNICAL INFORMATION

Line Power: 120, 230VAC 50/60 HZ, Single Phase ONLY

Reservoir Capacity: 0.78 gal /2.96 l

Coolant Type & Ratio: 3 parts distilled water : 1 part ethylene glycol :

1 tablespoon liquid glycerin

Flow Rate:

Section 2

ELECTRICAL INFORMATION

Pump: 120VAC, 50/60 Hz, 0.50 amps

Input Taps: 120, 230VAC 50/60 Hz

AC Power for Cooling Unit: Panel switchable, rear panel fuse holder

Front Panel Indicators: Spinning Flow Indicator

Section 3 MECHANICAL INFORMATION

Dry Weight: 12.9 lbs. / 5.85 Kg

Height: 5.5 in. / 14.0 cm

Width: 8.5 in. / 21.6 cm

Depth: 19 in. / 48.3 cm

Pump: Gear Mesh Pump

CAUTIONS:

Read and follow instructions prior to performing operational functions.

Section 4 POWER TAPPING

WARNING

DISCONNECT UNIT FROM ALL POWER SOURCES PRIOR

TO CHANGING POWER TAPS.

ELECTRIC SHOCK CAN KILL

Remove the cover of the CobraCooler

®

Remove the cover of the CobraCooler

Remove the cover of the CobraCooler , looking down into the unit, locate the

power tapping terminal strip.

Move the jumper and affi x to the required input power tap setting.

Change the plug on the end of the cable to suite the required input power

type.

PSI ML/MIN OZ/MIN GAL/MIN

0

1550

55

.43

5

1300

46

.36

10

1050

37

.29

15

750

26

.20

20

70

3

.023