MK Products CobraCooler 2005 User Manual
Page 9
Owner’s Manual - Page 8
Section 1 TECHNICAL INFORMATION
Line Power: 120, 230VAC 50/60 HZ, Single Phase ONLY
Reservoir Capacity: 0.78 gal /2.96 l
Coolant Type & Ratio: 3 parts distilled water : 1 part ethylene glycol :
1 tablespoon liquid glycerin
Flow Rate:
Section 2
ELECTRICAL INFORMATION
Pump: 120VAC, 50/60 Hz, 0.50 amps
Input Taps: 120, 230VAC 50/60 Hz
AC Power for Cooling Unit: Panel switchable, rear panel fuse holder
Front Panel Indicators: Spinning Flow Indicator
Section 3 MECHANICAL INFORMATION
Dry Weight: 12.9 lbs. / 5.85 Kg
Height: 5.5 in. / 14.0 cm
Width: 8.5 in. / 21.6 cm
Depth: 19 in. / 48.3 cm
Pump: Gear Mesh Pump
CAUTIONS:
Read and follow instructions prior to performing operational functions.
Section 4 POWER TAPPING
WARNING
DISCONNECT UNIT FROM ALL POWER SOURCES PRIOR
TO CHANGING POWER TAPS.
ELECTRIC SHOCK CAN KILL
Remove the cover of the CobraCooler
®
Remove the cover of the CobraCooler
Remove the cover of the CobraCooler , looking down into the unit, locate the
power tapping terminal strip.
Move the jumper and affi x to the required input power tap setting.
Change the plug on the end of the cable to suite the required input power
type.
PSI ML/MIN OZ/MIN GAL/MIN
0
1550
55
.43
5
1300
46
.36
10
1050
37
.29
15
750
26
.20
20
70
3
.023