beautypg.com

Safety considerations, Electric arc welding equipment – MK Products CobraTurn Digital Turntable User Manual

Page 4

background image

SAFETY CONSIDERATIONS

ELECTRIC ARC WELDING EQUIPMENT

CAUTION : READ BEFORE ATTEMPTING INSTALLATION, OPERATION OR

MAINTENANCE OF THIS EQUIPMENT

1-1 INTRODUCTION

This equipment is intended for ultimate

application by commercial/industrial

users and for operation by persons

trained and experienced in the use and

maintenance of welding equipment.

Operation should not be undertaken

without adequate training in the use of

such equipment. Training is available

from many public and private schools or

similar facilities.
Safe practices in the installation, opera-

tion and maintenance of this equipment

requires proper training in the art, a

careful study of the information provided

with the equipment, and the use of

common sense. Rules for safe use

are generally provided by suppliers of

welding power sources, compressed

gas suppliers, and electrode suppliers.

Careful compliance with these rules will

promote safe use of this equipment.
The following Safety Rules cover some

of the more generally found situations.

READ THEM CAREFULLY. In case of

any doubt, obtain qualified help before

proceeding.

1-2 GENERAL PRECAUTIONS

A. Burn Prevention

ELECTRIC ARC WELDING PRODUCES

HIGH INTENSITY HEAT AND ULTRA-

VIOLET RADIANT ENERGY WHICH

MAY CAUSE SERIOUS AND PER-

MANENT EYE DAMAGE AND WHICH

MAY DAMAGE ANY EXPOSED SKIN

AREAS.
Wear helmet with safety goggles or

glasses with side shields underneath,

appropriate filter lenses or plates (pro-

tected by clear cover glass). This is a

must for welding or cutting (and chipping)

to protect the eyes from radiant energy

and flying metal. Replace cover glass

when broken, pitted, or spattered.
Medical first aid and eye treatment. First

aid facilities and a qualified first aid

person should be available for each shift

unless medical facilities are close by for

immediate treatment of flash burns of

the eyes and skin burns.
Wear protective clothing - leather (or

asbestos) gauntlet gloves, hat, and high

safety-toe shoes. Button shirt collar and

pocket flaps, and wear cuffless trousers

to avoid entry of sparks and slag.
Avoid oily or greasy clothing. A spark

may ignite them.
Flammable hair preparations should not

be used by persons intending to weld

or cut.

Hot metal such as electrode stubs and work

pieces should never be handled without

gloves.
Ear plugs should be worn when working

on overhead or in a confined space. A

hard hat should be worn when others work

overhead.

B. Toxic Fume Prevention

WARNING: The use of this product may

result in exposure to chemicals known

to the State of California to cause cancer

and birth defects or other reproductive

harm.
Adequate ventilation. Severe discomfort,

illness or death can result from fumes,

vapors, heat, or oxygen enrichment or

depletion that welding (or cutting) may

produce. Prevent them with adequate

ventilation. NEVER ventilate with oxygen.
Lead-, cadmium-, zinc-, mercury-, beryl-

lium-bearing and similar materials, when

welded or cut, may produce harmful con-

centrations of toxic fumes. Adequate local

exhaust ventilation must be used, or each

person in the area, as well as the operator,

must wear an air-supplied respirator. For

beryllium, both must be used.
Metals coated with or containing materials

that emit toxic fumes should not be heated

unless coating is removed form the work

surface, the area is well ventilated, or the

operator wears an air-supplied respirator.
Work in a confined space only while it is

being ventilated and, if necessary, while

wearing an air-supplied respirator.
Gas leaks in a confined space should be

avoided. Leaked gas in large quantities can

change oxygen concentration dangerously.

Do not bring gas cylinders into a confined

space.
Leaving confined space, shut OFF gas

supply at source to prevent possible accu-

mulation of gases in the space if down-

stream valves have been accidentally

opened or left open. Check to be sure that

the space is safe before reentering it.
Vapors from chlorinated solvents can be

decomposed by the heat of the arc (or

flame) to form PHOSGENE, a highly toxic

gas, and other lung and eye irritating prod-

ucts. The ultraviolet (radiant) energy of the

arc can also decompose trichloroethylene

and perchloroethylene vapors to form

phosgene. DO NOT WELD or cut where

solvent vapors can be drawn into the

welding or cutting atmosphere or where

the radiant energy can penetrate to atmo-

spheres containing even minute amounts of

trichloroethylene or perchloroethylene.

C. Fire and Explosion Prevention

Causes of fire and explosion are: com-

bustibles reached by the arc, flame,

flying sparks, hot slag, or heated mate-

rial, misuse of compressed gases and

cylinders, and short circuits.
BE AWARE THAT flying sparks or falling

slag can pass through cracks, along

pipes, through windows or doors, and

through wall or floor openings, out of

sight of the goggled operator. Sparks

can fly many feet.
To prevent fires and explosion:
Keep equipment clean and operable,

free of oil, grease, and (in electrical

parts) of metallic particles that can cause

short circuits.
If combustibles are in area, do NOT weld

or cut. Move the work if practicable,

to an area free of combustibles. Avoid

paint spray rooms, dip tanks, storage

areas, ventilators. If the work cannot

be moved, move combustibles at least

35 feet away, out of reach of sparks and

heat; or protect against ignition with

suitable and snug-fitting, fire-resistant

covers or shields.
Walls touching combustibles on opposite

sides should not be welded on (or cut).

Walls, ceilings, and floor near work

should be protected by heat-resistant

covers or shields.
Fire watcher must be standing by with

suitable fire extinguishing equipment

during and for some time after welding

or cutting if:
1. Appreciable combustibles (including

building construction) are within 35 feet.
2. Appreciable combustibles are further

than 35 feet, but can be ignited by

sparks.
3. Openings (concealed or visible) in

floors or walls within 35 feet may expose

combustibles to sparks.
4. Combustibles adjacent to walls, ceil-

ings, roofs, or metal partitions can be

ignited by radiant or conducted heat.
Hot work permit should be obtained

before operation to ensure supervisor’s

approval that adequate precautions have

been taken.
After work is done, check that area is

free of sparks, glowing embers, and

flames.
An empty container that held combus-

tibles, or that can produce flammable or

toxic vapors when heated, must never

be welded on or cut, unless container

has first been cleaned in accordance

with industry standards.