Pro Series Owner’s Manual - Page 13

JP1: Post-Purge Settings & Adjustments

The Post-Purge Jumper/Pot Configuration at JP1 has 2 available settings: 2 sec. fixed and variable

from 0-5 seconds.
By default, the two-pin jumper across the top-and-middle pins, is configured for 2 sec. Just to the

left of the jumper is a ¾-turn pot, P1, which is used with the variable setting. For the 0-5 second

range, move the jumper from the top-and-middle to the middle-and-bottom pins (Shown above).
Timing adjustment for the variable settings are as follows: Move the jumpers to variable setting

location. Turn potentiometer screw (Small flat or cross-head) half way. Upon release of gun

trigger, count time between yellow Gas Solenoid LED (L1) and green Trigger LED (L3). Adjust as

necessary.

JP2: Pre-Purge Settings & Adjustments

The Pre-Purge Jumper/Pot Configuration at JP2 has 3 available settings: 0.25 sec. fixed, variable

from 0-1 sec. or variable from 0-5 seconds.

By default, the twin two-pin jumpers, across rows 1 & 3, are configured for 0.25 sec. Just to the left

of the jumpers is a ¾-turn potentiometer (pot) P2, which is used with both variable settings. For the

0-1 sec. range, move the jumpers across rows 3 & 5. For the 0-5 second range, move the jumpers

across rows 5 & 7 (Shown above).
Timing adjustment for the variable settings are as follows: Move the jumpers to either variable

setting location. Turn potentiometer screw (Small flat or cross-head) half way. Pull gun trigger and

count time between red contactor wire feed LED (L2) and yellow Gas Solenoid LED (L1). Adjust pot

screw as necessary.

JP3: Gas/Purge Jumper

Changing the position of the JP3 jumper changes the configuration of the pre & postpurge

sequences. Refer to Figure 5 for the desired pre and postpurge sequence. Once the desired

sequence is selected, relocate on JP3 jumper from its horizontal default pattern (top right) to its new

vertical sequence positurn.

Main PC Board: Jumper Functions

Rows 1 & 3: 0.25 sec. fixed

Rows 3 & 5: 0-1 sec.

Rows 5 & 7: 0-5 sec.

Middle/Bottom: 0-5 sec.

Top/Middle: 2 sec fixed