Installation – Microsens MS400940 User Manual
Page 7

5
Installation
To install the Power over Ethernet Splitter, please follow the below steps.
1. Using RJ-45 cable to connect the Data in port on the Power over
Ethernet Splitter with the PoE Switch/HUB (which is Data out port). If
the Switch/HUB does not support PoE function, you need to install a
PoE injector between Switch/HUB and Power over Ethernet Splitter.
2. Using RJ-45 cable to connect the Data out port on the Power over
Ethernet Splitter with the PD (Such as Router, Access Point
…etc.)
3. Choose the power cable (Internal Diameter 2.0mm or 2.5mm) and plug
into the Power out port on the Power over Ethernet Splitter.
4. Plug in the power cable of the Power over Ethernet Splitter to the PD
’s
power plug.
5. Adjust the Voltage for PD; switch the DIP setting on the Power over
Ethernet Splitter. It supports four type of voltage
– 5V, 7.5V, 9V and
12V. The default value will be set on 5V. When you change voltage
by DIP switching to different voltage, the Power over Ethernet Splitter
must be in powered off status.
6. Before starting, make sure all connections are correct and the voltage is
right.
The Power over Ethernet Splitter connects to the Switch or POE
Injector is in Data in port.
The Power over Ethernet Splitter connects to the device with two
connection ports
– Data out and Power out.
The voltage has four types
– 5V, 7.5V, 9V and 12V.