Wiring the power inputs – Microsens MS655033X User Manual
Page 13

Wiring the Power Inputs
Please follow the steps below to wire power lines from the terminal block
to the compliant external DC power source.
1. Before wiring, make sure the power source is disconnected.
2. Using the wire-stripping tool, strip a short piece of insulation from the
output wires of the DC power source.
3. Identify the positive and negative feed positions for the terminal block
connection. See the symbols printed on the panel indicating the
polarities and DC input power range in voltage.
Plugs for Power 1 & Power 2
4. Insert the exposed wires into the terminal block plugs. Only wires with
insulation should extend from the terminal block plugs. Note that the
polarities between the wires and the terminal block plugs must be
positive to positive and negative to negative.
5. Use a slotted screwdriver to tighten the captive screws.
¾
Use Copper Conductors Only, 60/75
°
C, tightening to 5 lb-in
¾
The wire gauge for the terminal block should be in the range
between 12~ 24 AWG.
ATTENTION
10