Netzteile konverter modul, Configuration, Gigabit ethernet access module page 3/6 – Microsens Gigabit Ethernet 3-port Converter Module 1000Base-T/X User Manual
Page 3

Gigabit Ethernet Access Module
Page 3/6
MICROSENS GmbH & Co. KG - Küferstr. 16 - D-59067 Hamm - Tel. +49 (0)2381/9452-0 - Fax -100 -
Configuration
The converter module is designed for the insertion into the MICROSENS modular
chassis. It can be combined with all other converter modules of the same series.
The power supply is done by a central power supply via the backplane of the chassis.
Together with the power supply (MS416004 or MS416004M – manageable version) it is
possible to insert up to 12 modules into one 3 HU chassis (MS416001 or MS416001M –
manageable version).
Optional it is possible to insert a second redundant power supply. Then the number of
modules is then reduced to 10. Empty slots can be coveres with the blind covers. The
blind covers should be ordered separately.
Converter module
MICROSENS
Status
Power Supply
MICROSENS
Status
Power S upply
Netzteile
Konverter Modul
Repeater MM/S M
MICROSENS
Tx
Tx
Rx
Al arm
Rx
PW R
LNK 1
GBE
AL ARM
LNK2
FCH
Mu lti mo d e
Si n gl e M od e
1
2
Repeat er MM/SM
MI CRO SENS
Tx
Tx
Rx
Alar m
Rx
P WR
L NK1
GB E
ALAR M
LNK 2
FC H
M ul ti mod e
Si ng le M od e
1
2
Repeater MM/S M
M ICROSEN S
Tx
Tx
Rx
Al arm
Rx
PW R
LNK 1
GBE
AL AR M
L NK2
F CH
Mu lti mo de
Si n gl e Mo de
1
2
Repeater MM/S M
MI CRO SENS
Tx
Tx
Rx
Al arm
Rx
P WR
L NK 1
GB E
ALARM
LNK 2
FC H
Mu l tim od e
S in gl e M od e
1
2
Blind cover
Power supplies
Beside the 3HU chassis, a 1 HU chassis for three modules (horizontal mounted) is also
available. This chassis (MS416006) has one integrated power supply, which can be
redundant (MS416007) if required.
In addition to the 19" chassis, desktop chassis for the mounting of one (MS417001) or
two (MS417041) modules are available. Together with the wall bracket (MS417001-WH)
it is possible to fix these desktop chassis on the wall.
The SNMP and web based management features of the system is provided by the
management master module (MS416020-B). Be Aware: it must be considered that the
chassis (e.g. MS416001M) and the power supply (MS416004M) support the management
too (ordered products with an “M”).
To access the data of the modules with the SNMP management, it is necessary to
integrate the structure of the data into the existing management platform using the
MIB file. The MICROSENS-MIB can be downloaded with http download from the
management master. The MIB file has an ASCII format.