Led indicators – Microsens MS655208 User Manual

Page 10

background image

7

Note

The wire gauge for the terminal block should be in the range

between 12~ 24 AWG.

LED Indicators

There are few LEDs display the power status and network status

located on the front panel of the Industrial switch, each of them has their

own specific meaning as the table below.

LED

Color

Description

P1

Green

On

Power input 1 is active

Off

Power input 1 is inactive

P2

Green

On

Power input 2 is active

Off

Power input 2 is inactive

Fault

Red

On

Power input 1 or 2 is inactive

Off

Power input 1 and 2 are both functional, or no power

inputs

1 ~ 8

(Upper LED)

Green

On

Connected to network

Flashing

Networking is active

Off

Not connected to network

1 ~ 8

(Lower LED)

Green

On

Connected to network at speed of 1000Mbps

Off

Not connected to network or not working at speed of

1000Mbps

2. To tighten the wire-clamp screws for preventing the DC

wires to loose.