Wiring the Fault Alarm Contact

The fault alarm contact is in the middle of terminal block connector as the

picture shows below. Inserting the wires, it will detect the fault status

which the power is failure or port link failure (for managed model) and form

an open circuit.

Note

The wire gauge for the terminal block should be in the range

between 12~ 24 AWG.

LED Indicators

There are few LEDs display the power status and network status

located on the front panel of the Industrial switch, each of them has its

own specific meaning as below table.

LED

Color

Description

P1

Green

On

Power input 1 is active

Off

Power input 1 is inactive

P2

Green

On

Power input 2 is active

Off

Power input 2 is inactive

Fault

Red

On

Power input 1 or 2 is inactive

Off

Power input 1 and 2 are both functional, or no power

Insert the wires into the fault alarm contact (No. 3 & 4)