12

SYSTEM BUS
INTERFACE:

VME bus A16:D8, slave
Access:

Short Supervisor I/O (2Dh)
Short Non-priviledged I/O (29h)

IRQ levels:

1..7, programmable

DATA FORMAT: packed BCD

PERIODIC
INTERRUPTS:

none, 10ms, 100ms, 1s, 10s, 1min, 10min, or 1h

POWER
REQUIREMENT: +5V @ 320mA

PHYSICAL
DIMENSION:

3U Euro card, 6U front panel optional

AMBIENT
TEMPERATURE: 0 ... 50°C

HUMIDITY:

max. 85 %

CE Label

This device conforms to the directive 89/336/EWG on the approxi-
mation of the laws of the Member States of the European Community
relating to electromagnetc compatibility.