Specifications

Signal Input:

potential free

Impedance 50Ohms also available 600 Ohms

Amplitude:

abt. 600mV...8V peak to peak (Mark)

Supported Time Codes:

IRIG-A133 and IRIG-B123
AFNOR NFS 87-500 on request

PPS-Strobe Accuracy:

+/-5us referred to 'On Time'

Free running mode:

changeover to crystal time base,
accuracy abt. 1e-6s/s if decoder was synchroni-
zed for at least 1h.

Backup Battery:

The internal hardware clock (RTC) is supplied

from a backup battery in case of an operating
voltage failure. The lifetime of the Lithium-Battery
is at least 10 years.

Security of operation:

hardware watchdog generates a reset in case of

brown out. Software watchdog generates reset in
case of improper program execution

Initialization:

Initial time and date of hardware clock can be set
by a Meinberg standard telegram via serial port
COM0.

Pulse Outputs:

one PPS-Output, TTL Level, 200ms length,

positive and inverted.
four TTL pulse outputs, DCF-Simulation
or positive PPS
four 20mA current loop outputs, DCF-Simulation
or positive PPS

Serial Ports:

two independent RS232 ports

Baud rates:

configurable : 2400Bd, 4800Bd ,9600B,19200Bd

Framing:

configurable: 7E2, 8N1