beautypg.com

Meinberg GPS164xHS User Manual

Page 21

background image

21

SERIAL PORTS:

2 independant asynchronous serial ports

COM0 (RS-232)
Baud Rate:

300 up to 19200

Framing:

7N2, 7E1, 7E2, 8N1, 8N2, 8E1

COM1 (RS-232, optional RS-485)
Baud Rate:

300 up to 19200

Framing:

7N2, 7E1, 7E2, 8N1, 8N2, 8E1

time string selectable for COM0 and COM1
'standard Meinberg', 'SAT', 'Uni Erlangen (NTP)',
'NMEA-183' ( RMC ), and 'Computime'

default settings:

COM0:

19200, 8N1

COM1:

9600, 8N1

'standard Meinberg' for COM0 and COM1
time string per second
mode of operation 'if sync'

TIME CODE
OUTPUTS:

modulated via BNC-connector:
IRIG:

3V

PP

(MARK), 1V

PP

(SPACE) into 50

Ω

AFNOR:

2.17V

SS

(MARK), 0.688V

SS

(SPACE) into 50

Ω

modulated via DSUB-connector:
Field effect transistor with internal pull-up (470

Ω) to +5V

Data of transistor:
Uds

max

= 100 V, Id

max

= 150 mA, P

max

= 250 mW

TTL into 50

Ω

RS422

DCF77
EMULATION:

AM-modulated 77.5 kHz carrier frequency
usable as replacement for a DCF77 antenna
output level approximately -55 dBm (unmodulated)

STATUS
INDICATION:

receiver status:
Lock:

the reciever was able to compute its position

after

power-up

Fail:

the receiver is asynchronous to the GPS-system

status of the pulse outputs:
a burning LED indicates the active state of the corresponding
optocoupler/PhotoMOS relay

This manual is related to the following products: