Measurement Computing TempScan 1100 User Manual
Tempscan, Multiscan quick start

446-0940, rev 4.0
324602C-01
TempScan
&
MultiScan Quick Start
High-Speed Temperature & Voltage Scanning Instruments
Before you get started
Verify that you have the following items.
TempScan/1100 or MultiScan/1200
Data Acquisition CD (8.1.2 or higher)
Monitor: SVGA, 1024 x 768 screen resolution
Windows XP users
:
PC with
I
ntel
™
Pentium [or equivalent]; 1 GHz
512 MB memory; 10 GB disk space
Windows Vista users:
PC must be Windows Vista Premium Ready
Step 1 - Install Software
IMPORTANT ! Software must be installed first!
1. Close all running applications on the host PC.
2. Insert the Data Acquisition CD (8.1.2 or higher) into your CD-ROM drive and wait for the PC to auto-run. An Opening
Screen will appear. If AutoRun is disabled: (a) right click Windows Start menu, (b) select Explore; and (c) double-click
MasterSetup.exe. As an alternative to using the CD, you can download software from
3. Click the <ENTER SETUP> button.
Note: If you are downloading software from our website, follow instructions provided there.
4. From the hardware selection screen [which follows a licensing agreement], select the TempScan/1100 or MultiScan/1200, as
applicable; then follow the on-screen instructions.
NOTE: To enable all ChartView features: (a) From ChartView’s main window, open the File pull-down menu,
(b) select Authorization, (c) enter
C3523DFA6C0A
in the dialog box and apply the code.
Step 2 – Check Hardware
1. Verify that the voltage stated on the sticker [near the power switch] matches the voltage
of your intended AC power supply. If you need to change the voltage, refer to your
user’s manual.
2. Check the DIP switch, located on the rear panel. Your user’s manual discusses setting
options.
Step 3 - Connect to the Host PC
Prior to making a serial connection, make sure that the host PC’s serial
(COM) port is available and properly configured to match the DIP
switch setting in Step 2. Do this by navigating from the Windows
Desktop, i. e., Control Panel System Device Manager tab, then
clicking on Ports (COM & LPT).
Using a serial communications cable, connect the TempScan [or MultiScan] to the host
PC by one (and only one) of the following methods:
USB
Requires an adapter kit. To connect the TempScan [or MultiScan] to a USB port you will need a RS-232 to
USB Interface Adapter Kit p/n CA-232-USB-KIT (available from MCC). Refer to the associated Quick Start
document (QS RS-232_to_USB_Interface.pdf) for a list of the kit’s contents and for RS-232 to USB conversion
instructions. The pdf is included on your Data Acquisition CD (rev 8.1.2 and higher).
Use only
one of
these 3
connection
options.
RS-232
Requires a DB9F to DB9F serial communication cable. Connect the cable from the TempScan [or MultiScan]
Serial Port to a RS-232 Serial Port on the host PC.
RS-422
Requires a DB9F to DB25F serial communication cable. Connect the DB9F to the TempScan [or MultiScan]
Serial Port. Connect the DB25F to an RS-422 Serial Port on the host PC.
Note 1:
Measurement Computing offers a CA-47 three-connector serial communications cable. The single cable has two DB9F connectors
and one DB25F connector. Note that the CA-232-USB-KIT includes a CA-47 cable.