Step 4 - Configure Computer Network Settings

Applies to “dedicated networks” only. See user’s manual in regard to other network types.

We recommend that you discuss this procedure with your Network Administrator before
proceeding

. Note that the StrainBook/616 Ethernet port typically requires 30 seconds after

power-up [to configure] before the unit can be accessed via the network.

1. Open the Control Panel by navigating from the Windows Desktop: Start Menu Settings Control Panel.
2.

Double-click the “Network Connections” icon.

3.

Double-click the icon for the network that the StrainBook/616 is connected to.

4. In the “Local Area Connection Status” box, click on the <Properties> button.

The “Local Area Connection Properties” box will appear.

5. Double-click the “Internet Protocol (TCP/IP)” component.

The “Internet Protocol (TCP/IP) Properties” box will appear.

6. Select the “Use the following IP Address” radio button. (See figure at left).
7. Set the IP address field to 10.0.0.x , where x is some number from 1 to 254.

Make sure that each computer and each device on the dedicated network
has a unique IP address.

8. Set the Subnet mask to 255.0.0.0. Note that the remaining fields can be left as is.
9. Click <OK> on follow-up screens to exit.

Step 5 - Configure & Test the System

Using the Daq Configuration Applet

1. Open the Daq Configuration Applet.

a. Navigate from the Windows’ Desktop: Start Menu Settings Control Panel
b. From the Control Panel, double-click the Daq Configuration icon.

2. Add the StrainBook/616 to the list of installed devices.

a. Click the <Add Device> button. The “Select Device Type” box will appear.
b. Select the StrainBook/616 from the list of devices.
c. Click the <OK> button. The “Properties” box will appear for the selected StrainBook/616.
d. Enter the unit’s Serial Number.
e. Select the “Auto IP Setting” radio button. The IP Address of the StrainBook/616

will be calculated automatically and displayed in the IP Address field.

3. Test the System.

a. Click the “Test Hardware” tab.
b. Click the <TCP/IP Test> button. This tests the Transmission Control Protocol / Internet Protocol.
c. Upon completion of the TCP/IP test, click the <Resource Test> button.

When testing, if the unit does not respond within 30 seconds perform the following steps:
1) reboot the system, 2) upon power-up, re-open the Daq Configuration applet,
3) select another configuration setting, 4) reinitiate the test.

Step 6 - Connect Data Acquisition Signal Lines

Prior to making signal connections review the Specifications chapter of your user’s manual to ensure that your intended signal

inputs do not exceed the specified limits. The manual is included in PDF format on your CD.

Internet Protocol (TCP/IP) Properties

(Partial View)