beautypg.com

Dbk65 specifications …… 12, Dbk65 specifications – Measurement Computing DBK65 User Manual

Page 12

background image

DBK65 pg. 12

987693

DBK Option Cards and Modules

DBK65 Specifications

Dimensions: 285 mm W x 220 mm D x 45 mm H (11” x 8.5” x 1.75”)

Weight: 1.13 kg (2.5 lbs.)

Operating Temperature: -30°C to +70°C

System Connector: DBK37 male, mates with P1 connectors

Transducer Connectors: 8 removable screw-terminal blocks. Each block has 6 terminals.

Power Connectors: DIN5 Power In, DIN5 Power Out

DC Power Input: +10 to +30 VDC

DC Power Required (through DBK65 Power-In DIN5): 15 V @ 833 mA, 20 V @ 625 mA, assuming max load

DC Power Required (from P1-based host acquisition device): 25 mA from ±15 V, 755 mW total

Gain Ranges: x1

Inputs: 8 differential voltage inputs

Maximum Voltage Range: ±10 V

Input Impedance: 20M Ohm

Accuracy: ±[0.025% +150 µV] (typ), ±[0.1% +250 µV] (max)

Noise: 60 µV

RMS

(typ)

Temperature Coefficient: 10ppm for every degree outside the range of 0° to 50°C

Maximum Signal Input Voltage (without damage): ±35 V

3 dB Bandwidth: 2.6 MHz

CMRR: 80 dB (typ)

Output Voltage: Each channel, jumper-selectable to +5 V, +10 V, +15 V, and +24 V

or to a custom voltage setting within the range of +5 to +20 V (user set via resistor)

Voltage Accuracy: ±2% (typical)

Current Limit: 100 mA per channel

Load Regulation: 5% (typ)

Total Output: 240 mA max, total of all 8 channels

Accessories and Cables

Rack mount kit

RackDBK3

Shielded P1 T cable for use with DaqBook/2020, LogBook/360, WBK40, WBK41 CA-255-4T

Shielded P1 T cable for use with DaqBook/2001, /2005, LogBook/300, DaqLab/2001, /2005 CA-255-2T

Ribbon cable for use with DaqScan CA-37-x

(see note)

Note: The CA-37-x ribbon cable can also be used in lieu of the CA-255-x molded T cables.

The following 4 graphs illustrate the current limiting capabilities of the DBK65 for 5, 10, 15, and 24 VDC excitation

values.