beautypg.com

Connector w3, Screw terminal connectors, Usb connector – Measurement Computing USB-201-OEM User Manual

Page 10: Led indicators, Signal connections, Analog input, External pacer i/o

background image

USB-201-OEM User's Guide

Functional Details

10

Connector W3

Header connector W3 provides connections for the analog inputs and the analog ground reference.

W3 pin descriptions

Pin

Signal name

Pin description

Pin

Signal name

Pin description

1

CH0

Channel 0

2

AGND

Analog ground

3

CH1

Channel 1

4

AGND

Analog ground

5

CH2

Channel 2

6

AGND

Analog ground

7

CH3

Channel 3

8

AGND

Analog ground

9

CH4

Channel 4

10

AGND

Analog ground

11

CH5

Channel 5

12

AGND

Analog ground

13

CH6

Channel 6

14

AGND

Analog ground

15

CH7

Channel 7

16

AGND

Analog ground

Figure 4. Connector W3 pinout

Screw terminal connectors

Screw terminals J1 through J8 are unpopulated. When populated the screw terminals provide alternative
connections to the header connectors. Refer to the Specifications chapter for screw terminal pinouts.

USB connector

The USB connector provides +5 V power and communication. No external power supply is required.

LED indicators

The device has two LED indicators –

Status

and

Activity.

 The

Status

LED turns on when the device is detected and installed on the computer.

 The

Activity

LED blinks when data is transferred, and is off otherwise.

Refer to Figure 2 on page 9 for the location of these LEDs.

Signal connections

Analog input

You can connect up to 8 single-ended inputs to screw terminals

CH0

to

CH7

. The input voltage range is ±10 V.

Single-ended mode requires two wires; connect one wire to the signal you want to measure (

CHx

), and connect

a second wire to the analog ground reference (

AGND

).

External pacer I/O

The USB-201-OEM provides one external clock input (

AICKI

) and one clock output (

AICKO

) for the analog

input pacer. You can connect an external clock signal to

AICKI

.

When using the internal clock,

AICKO

outputs the

ADC sample clock.

This manual is related to the following products: