Step 4: prepare the wall & upper cabinet, Caution – Maytag MMV4184AAW Installation User Manual
Page 13

13
Measure And Track/Tape Up The Templates
1. Using a plumb line and (metal) measuring tape, find and mark
the vertical center line on the back wall, as in Figure 22.
2. Find and mark one or two points where the studs are on the
wall. (Studs are normally 16 inches apart). Then measure and
mark the stud locations. If you cannot find any wall stud,
consult a local building contractor.
CAUTION
DO NOT ATTEMPT TO INSTALL THE MICRO-
WAVE OVEN IF YOU CANNOT FIND A WALL
STUD.
3. Line up the plumb line on the wall with the center line on the
mounting plate.
NOTE:
Be sure the minimum width is 30 inches and the distance
from the top of the wall template to the range or counter
top is at least 30 inches. See Figure 22.
4. Center mounting plate in operating by lining up the plumb line
on wall with centerline on mounting plate. Make sure the
minimum width is 30 inches and that the top of the mounting
plate is located a minimum of 30 inches above the cooking
surface. See Figure 23.
NOTE:
If the cabinets are not plumb, adjust the mounting plate
to the cabinets. If the front edge of the cabinet is lower
than the back edge, adjust the mounting plate to be level
with the cabinet front.
5. Measure the bottom of the upper cabinet frame. Trim the
edges A, B and C on the upper cabinet template so that the
template will fit on the bottom of the upper cabinet. If upper
cabinet has a recessed frame, trim the template so it fits inside
the recessed area. Align the centerline of the upper cabinet
template with the centerline of the mounting plate, then
securely tape or tack the upper cabinet template in place. See
Figure 23.
To avoid personal injury or property damage, do not attempt to install this microwave
oven if you cannot find a wall stud.
STEP 4: Prepare The Wall & Upper Cabinet
Figure 22
Figure 23
W A R N I N G