Maytag UXT4236AAB Dimension Guide User Manual
7" (17.8 cm) vent system, Ab c d
x 10" (8.3 x 25.4 cm) vent system
x 10" (8.3 x 25.4 cm) vent system
Maximum length
= 35 ft.
(10.7 m)
1 - 90° elbow
= 5 ft.
(1.5 m)
8 ft. (2.4 m) straight
= 8 ft.
(2.4 m)
1 - wall cap
= 0 ft.
(0 m)
Length of
x
10" (8.3 x 25.4 cm) system
= 13 ft.
(3.9 m)
NOTE: Flexible vent is not recommended
x 10"
(8.3 x 25.4 cm)
90° elbow =
5 ft. (1.5 m)
x 10"
(8.3 x 25.4 cm)
flat elbow =
12 ft. (3.7 m)
x 10"
(8.3 x 25.4 cm)
wall cap =
0 ft. (0 m)
2 ft.
(0.6 m)
6 ft. ( 1.8 m)
wall cap
x 10"
(8.3 x 25.4 cm)
elbow
Maximum length
= 35 ft.
(10.7 m)
1 - 90° elbows
= 5 ft.
(1.5 m)
8 ft. (2.4 m) straight
= 8 ft.
(2.4 m)
1 - wall cap
= 0 ft.
(0 m)
Length of 7"
(17.8 cm) system
= 13 ft.
(3.9 m)
NOTE: Flexible vent is not recommended
7" (17.8 cm) vent
system
x 10"
(8.3 x 25.4 cm) to
7" (17.8 cm) =
4.5 ft. (1.4 m)
90° elbow =
5 ft. (1.5 m)
45° elbow =
2.5 ft. (0.8 m)
x 10"
(8.3 x 25.4 cm)
to 7" (17.8 cm)
90° elbow =
5 ft. (1.5 m)
7" (17.8 cm)
wall cap =
0 ft. (0 m)
7" (17.8 cm)
vent system
Wall cap
90˚ elbow
2 ft
(0.6 m)
6 ft (1.8 m)
18" (45.7 cm)
min. clearance
upper cabinet
to countertop
36" (91.4 cm)
base cabinet
height
13" (33.0 cm)
cabinet depth
30" (76.2 cm) or
36" (91.4 cm) min.
cabinet opening width
18"(45.7 cm) min.
24" (61.0 cm)
suggested max.
bottom of cabinet
to cooking surface
Range Hood - 30" (76.2 cm) and 36" (91.4 cm)
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
UXT4230AA
UXT4236AA
Electrical: A 120 Volt, 60 Hz., AC only, 15-amp, fused
electrical circuit is required.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10240546A
07-30-09
CABINET OPENING DIMENSIONS
7
¹⁄₂
"
(19.1 cm)
2"
(5.1 cm)
1
¹⁄₂
"
(3.8 cm)
1"
(2.5 cm)
1
¹⁄₂
"
(3.8 cm)
6"
9"
(22.9 cm)
12"
(30.5 cm)
³⁄₄
"
(1.9 cm)
³⁄₈
"
(9.5 mm)
17
¹⁄₂
"
(44.5 cm)
29
⁷⁄₈" (75.9 cm) - 30" (76.2 cm) model
35
⁷⁄₈" (91.1 cm) - 36" (91.4 cm) model
(15.2 cm)
VENTING REQUIREMENTS
Roof Venting
Wall Venting
A. 7" (17.8 cm) round vent or a
3
¹⁄₄" x 10" (8.3 x 25.4 cm) vent
through roof
B. Round vent: use 7" (17.8 cm)
round damper
(purchased separately)
C. 18" (45.7 cm) - 24" (61.0 cm)
above cooking surface
D. Roof cap
A. 7" (17.8 cm) round vent or a
3
¹⁄₄" x 10" (8.3 x 25.4 cm) vent
through the wall
B. 3
¹⁄₄" x 10" (8.3 x 25.4 cm)
through the wall
C. 18" (45.7 cm) - 24" (61.0 cm)
above cooking surface
D. Wall cap
A
B
D
C
A
B
C
D