beautypg.com

Maytag UXT4236AAB Dimension Guide User Manual

7" (17.8 cm) vent system, Ab c d

background image

x 10" (8.3 x 25.4 cm) vent system

x 10" (8.3 x 25.4 cm) vent system

Maximum length

= 35 ft.

(10.7 m)

1 - 90° elbow

= 5 ft.

(1.5 m)

8 ft. (2.4 m) straight

= 8 ft.

(2.4 m)

1 - wall cap

= 0 ft.

(0 m)

Length of

x

10" (8.3 x 25.4 cm) system

= 13 ft.

(3.9 m)

NOTE: Flexible vent is not recommended

x 10"

(8.3 x 25.4 cm)
90° elbow =
5 ft. (1.5 m)

x 10"

(8.3 x 25.4 cm)
flat elbow =
12 ft. (3.7 m)

x 10"

(8.3 x 25.4 cm)
wall cap =

0 ft. (0 m)

2 ft.
(0.6 m)

6 ft. ( 1.8 m)

wall cap

x 10"

(8.3 x 25.4 cm)
elbow

Maximum length

= 35 ft.

(10.7 m)

1 - 90° elbows

= 5 ft.

(1.5 m)

8 ft. (2.4 m) straight

= 8 ft.

(2.4 m)

1 - wall cap

= 0 ft.

(0 m)

Length of 7"
(17.8 cm) system

= 13 ft.

(3.9 m)

NOTE: Flexible vent is not recommended

7" (17.8 cm) vent

system

x 10"

(8.3 x 25.4 cm) to
7" (17.8 cm) =

4.5 ft. (1.4 m)

90° elbow =
5 ft. (1.5 m)

45° elbow =
2.5 ft. (0.8 m)

x 10"

(8.3 x 25.4 cm)
to 7" (17.8 cm)

90° elbow =
5 ft. (1.5 m)

7" (17.8 cm)

wall cap =
0 ft. (0 m)

7" (17.8 cm)

vent system

Wall cap

90˚ elbow

2 ft

(0.6 m)

6 ft (1.8 m)

18" (45.7 cm)

min. clearance

upper cabinet

to countertop

36" (91.4 cm)

base cabinet

height

13" (33.0 cm)

cabinet depth

30" (76.2 cm) or

36" (91.4 cm) min.

cabinet opening width

18"(45.7 cm) min.

24" (61.0 cm)

suggested max.

bottom of cabinet

to cooking surface

Range Hood - 30" (76.2 cm) and 36" (91.4 cm)

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

UXT4230AA
UXT4236AA

Electrical: A 120 Volt, 60 Hz., AC only, 15-amp, fused
electrical circuit is required.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10240546A

07-30-09

CABINET OPENING DIMENSIONS

7

¹⁄₂

"

(19.1 cm)

2"

(5.1 cm)

1

¹⁄₂

"

(3.8 cm)

1"

(2.5 cm)

1

¹⁄₂

"

(3.8 cm)

6"

9"

(22.9 cm)

12"

(30.5 cm)

³⁄₄

"

(1.9 cm)

³⁄₈

"

(9.5 mm)

17

¹⁄₂

"

(44.5 cm)

29

⁷⁄₈" (75.9 cm) - 30" (76.2 cm) model

35

⁷⁄₈" (91.1 cm) - 36" (91.4 cm) model

(15.2 cm)

VENTING REQUIREMENTS

Roof Venting

Wall Venting

A. 7" (17.8 cm) round vent or a

3

¹⁄₄" x 10" (8.3 x 25.4 cm) vent

through roof

B. Round vent: use 7" (17.8 cm)

round damper
(purchased separately)

C. 18" (45.7 cm) - 24" (61.0 cm)

above cooking surface

D. Roof cap

A. 7" (17.8 cm) round vent or a

3

¹⁄₄" x 10" (8.3 x 25.4 cm) vent

through the wall

B. 3

¹⁄₄" x 10" (8.3 x 25.4 cm)

through the wall

C. 18" (45.7 cm) - 24" (61.0 cm)

above cooking surface

D. Wall cap

A

B

D

C

A

B

C

D