PRODUCT MODEL NUMBERS

UXT4130

UXT4136

Electrical:

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical

circuit is required.

30" (76.2 cm) Wall-Mount Canopy Range Hood

Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.

Vent System

Vent Piece
90° elbow

5.0 ft
(1.5 m)

3

¹⁄₄" x 10" (8.3 cm x

12.0 ft

25.4 cm) flat elbow

(3.7 m)

7" (17.8 cm) wall cap

0.0 ft
(0.0 m)

3

¹⁄₄" x 10" (8.3 cm x

4.5 ft

25.4 cm) to 7" (17.8 cm)

(1.4 m)

3

¹⁄₄" x 10" (8.3 cm x

5.0 ft

25.4 cm) to 7" (17.8 cm)

(1.5 m)

90° elbow

VENTING METHODS

NOTES:

Flexible vent is not recommended. Flexible vent creates both back
pressure and air turbulence that greatly reduce performance.

The vent system is optional for this model.

Vent system can terminate either through the roof or wall. Use 3

¹⁄₄" x

10" (8.3 x 25.4 cm) rectangular with a maximum vent length of 35 ft
(10.7 m).

Top Venting

Wall Venting

A. 3

¹⁄₄" x 10" (8.3 x 25.4 cm)

rectangular vent through the
roof (purchased separately).

B. Roof cap with damper

(purchased separately)

A. 3

¹⁄₄" x 10" (8.3 x 25.4 cm)

rectangular vent through the
wall or out the top (purchased
separately).

B. Wall cap with damper

(purchased separately)

A

B

A

B

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

PRODUCT DIMENSIONS

1"

(2.5 cm)

4

¹⁵⁄₁₆

"

(12.5 cm)

6

⁹⁄₁₆

" (16.7 cm) or

9

⁹⁄₁₆

" (24.4 cm)

29

¹⁵⁄₁₆

" (76.0 cm) or

35

¹⁵⁄₁₆

" (91.0 cm)

18

⁵⁄₈

"

(47.3 cm)

1¹⁄₂

"

(3.8 cm)

9"

(22.9 cm)

2"

(5.1 cm)

⁷⁄₈

"

(2.2 cm)

Ref. W10646403B

12/8/14

Page 1 of 2

1 - 90° elbow

= 5.0 ft (1.5 m)

1 - wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

Length of system

= 13.0 ft (3.9 m)

Maximum Recommended Length

3

¹⁄₄" x 10" (8.3 x 25.4 cm)

Rectangular Vent

= 35 ft (10.7 m)

Example vent system

Wall cap

90˚ elbow

2 ft (0.6 m)

6 ft (1.8 m)

This manual is related to the following products: