PRODUCT MODEL NUMBERS

UXW7230BSS

Electrical:

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical

circuit is required.

30" (76.2 cm) Wall-Mount Canopy Range Hood

Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.

Vent System

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft
(0.8 m)

90° elbow

5.0 ft
(1.5 m)

Maximum equivalent vent length is 35 ft (10.7 m).

The following example falls within the maximum recommended vent
length of 35 ft (10.7 m).
1 - 90° elbow

= 5.0 ft (1.5 m)

1 - wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

Length of system

= 13.0 ft (3.9 m)

VENTING METHODS

For Non-Vented (recirculating) Installations

If it is not possible to vent cooking fumes and vapors to the outside,
the hood can be used in the non-vented (recirculating) version, by
fitting a charcoal filter and the deflector. Fumes and vapors are recycled
through the top grille. See the “Assistance or Service” section for
information on ordering.

Roof Venting

Wall Venting

Non-vented

(recirculating)

A. Roof cap
B. 6" (15.2 cm)

round vent

A. Wall cap
B. 6" (15.2 cm)

round vent

A. Deflector
B. 6" (15.2 cm)

round vent

A

A

B

B

B

A

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

PRODUCT DIMENSIONS

*For non-vented (recirculating) installations

**For vented installations

30" (76.2 cm)

10"

(25.4 cm)

20" (50.8 cm)

14

¹⁄₈

"

(35.9 cm)

7

¹⁄₄

"

(18.4 cm)

8

¹⁄₈

"

(20.6 cm)

*28

⁷⁄₈

" (73.3 cm) min.

42

¹⁄₁₆

" (106.8 cm) max.

**28

³⁄₈

" (72.0 cm) min.

38" (96.5 cm) max.

1 " (3.8 cm)

Ref. W10646401B

12/8/14