INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.

Read and follow the instructions provided with any tools listed

here.

Tools needed

Parts needed

Check local codes and consult gas supplier. Check existing gas

supply and electrical supply. See “Electrical Requirements” and

“Gas Supply Requirements” sections.

Location Requirements

IMPORTANT:

Observe all governing codes and ordinances. Do

not obstruct flow of combustion and ventilation air.

It is the installer’s responsibility to comply with installation

clearances specified on the model/serial rating plate. The

model/serial rating plate is located at bottom front face

surface on the right-hand side of the oven frame.

The oven should be located for convenient use in the kitchen.

Recessed installation area must provide complete enclosure

around the recessed portion of the oven.

All openings in the wall or floor where oven is to be installed

must be sealed.

Cabinet opening dimensions that are shown must be used.

Given dimensions provide minimum clearance with oven.

Grounded electrical supply is required. See “Electrical

Requirements” section.

Proper gas supply connection must be available. See “Gas

Supply Requirements” section.

IMPORTANT

: To avoid damage to your cabinets, check with your

builder or cabinet supplier to make sure that the materials used

will not discolor, delaminate or sustain other damage. This oven

has been designed in accordance with the requirements of UL

and CSA International and complies with the maximum allowable

wood cabinet temperatures of 194°F (90°C).

Product Dimensions - Single Oven

Cabinet Dimensions - Single Oven

Single Oven Installed in Cabinet

NOTE:

For gas supply pipe, provide a 3" x 3" (7.6 cm x 7.6 cm)

opening in the back wall of the cabinet centered 7" (17.8 cm)

from the left rear corner and 3" above the bottom of the cabinet

cutout. Install a 120 volt electrical outlet in the back wall of the

cabinet centered 6" (15.2 cm) from the right rear corner and 4"

(10.2 cm) below the top of the cabinet cutout.

Tape measure

Phillips screwdriver

Flat-blade screwdriver

¹⁄₈" Flat-blade screwdriver

Level

Hand or electric drill

Wrench or pliers

Pipe wrench

¹⁵⁄₁₆" combination wrench

¹⁄₈" (3.2 mm) drill bit

(for wood floors)

Marker or pencil

Pipe-joint compound

resistant to LP gas

³⁄₁₆" (4.8 mm) carbide-tipped

masonry drill bit (for

concrete/ceramic floors)

Noncorrosive leak-detection

solution

For LP/Natural Gas
Conversions

½" combination wrench

7 mm nut driver

Masking tape

A. 22

¹⁄₄" (56.8 cm) max. recessed width

B. 39

¹⁄₄" (99.7 cm) max. overall height

C. 23

⁷⁄₈" (60.6 cm) overall width

D. 22

⁵⁄₈" (57.5 cm) max. recessed depth

E. 37

³⁄₄" (95.9 cm) recessed height

A.

24" (61 cm) min. cabinet width

B. 1

¹⁄₂" (3.8 cm) top of cutout to bottom of upper cabinet

door

C. 14" (35.6 cm) min. bottom of cutout to floor
D. 22

³⁄₈" (56.8 cm) cutout width

E. 1

¹⁄₂" (3.8 cm) min. bottom of cutout to top of cabinet door

F. 38" (96.5 cm) cutout height

A

B

C

D

E

A

B

C

D

E

F