Service and disassembly procedures, Warning – Maytag JDB1060AW User Manual
Page 37
37
16022783 Rev. 0
©2004 Maytag Appliances Company
Manifold
Water is supplied to the Top and Center Wash Arms
through this tube via the Pump Assembly. The Manifold
attaches to the Pump Assembly and runs vertically up the
rear and along the top of the Dishwasher Tub. The
Manifold is attached to the Tub with a clip.
Removal
1.
Disconnect power to the machine.
2.
Remove Racks, Stops, and Rack Assemblies.
3.
Spread Manifold Clips located on the back and top of
Tub.
4.
Tip top of Manifold towards door opening slightly.
Disengage the snap located on the bottom of the
Manifold, locking the Manifold to the Discharge
Housing .
5.
Slide Manifold back and out of the Pump Assembly.
Docking Station
The purpose of the Docking Station is to seal the water
flow to the upper rack Wash Arm.
Removal
1.
Slide Upper Rack forward to gain access to Docking
Station.
2.
Spread sides of Docking Station and remove from
Manifold.
Lower Wash Arm
Water is supplied to the Lower Wash Arm via the Pump
Assembly.
Removal
1.
Disconnect power to the machine.
2.
Remove lower Rack Assembly.
3.
Loosen Wash Arm Hub and Pivot.
4.
Lift Wash Arm out of Dishwasher.
Service and Disassembly Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge
capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be
connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational.