OWNER’S MANUAL

INSTALLATION

NOTICE: A qualified service per-
son must install heater. Follow
all local codes.

WARNING: Before installing

in a solid fuel burning fireplace,
the chimney flue and firebox must
be cleaned of soot, creosote,
ashes and loose paint by a quali-
fied chimney cleaner. Creosote
will ignite if highly heated. A dirty
chimney flue may create and dis-
tribute soot within the house. In-
spect chimney flue for damage. If
damaged, operate heater with flue
damper closed.

WARNING: Seal any fresh air

vents or ash clean-out doors lo-
cated on floor or wall of fireplace.
If not, drafting may cause pilot
outage or sooting. Use a heat-
resistant sealant. Do not seal
chimney flue damper.

WARNING: Never install the

heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater

• in high traffic areas
• in windy or drafty areas

CAUTION: This heater creates

warm air currents. These currents
move heat to wall surfaces next to
heater. Installing heater next to
vinyl or cloth wall coverings or
operating heater where impurities
(such as tobacco smoke, aromatic
candles, cleaning fluids, oil or
kerosene lamps, etc.) in the air
exist, may discolor walls.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP gas, do not install heater.
Call dealer where you bought heater for
proper type heater.

IMPORTANT:

Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation
, pages 4 through 6.

NOTICE: State or local codes may
only allow operation of this appli-
ance in a vented configuration.
Check your state or local codes.

WARNING: Make sure the re-

mote selector switch is in the
OFF position before installing
heater.

INSTALLATION AND
CLEARANCES (Vent-Free
Operation Only)

WARNING: Maintain the mini-

mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This
will ensure safe installation into a masonry
fireplace or factory-built U.L. 127 listed
vent-free firebox.

Minimum Wall and Ceiling
Clearances (see Figure 4)

A. Clearances from the side of the fire-

place opening to any combustible wall
should not be less than 16 inches.

B. Clearances from the top of the fireplace

opening to the ceiling should not be less
than 42 inches.

Figure 4 - Minimum Clearance to Wall and
Ceiling

LOG SIZING REQUIREMENTS

Minimum Firebox Size

Rear

Width

Log

Front At 14"

Size Height Depth Width Depth

24"

17"

14"

28"

21"

30"

17"

14"

34"

24"

MINIMUM FIREPLACE

CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

Side Wall

Ceiling

24"

16"

42"

42"

16"

Left and

Right Sides

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

Continued