Technical Features

ELECTRICAL FEATURES
Supply voltage

15 to 30 Vdc

Power consumption

6.5 W typical
9 W Max. (including startup current)
Main (isolated)

Auxiliary

Modem

RS232, RS485 full-duplex RS232

RS232

Other
Lonworks 1,25

Mb/s

Ethernet

10 or 100 Mb/s

DeviceNet

125 or 250 Kb/s

Communication Interfaces

Profibus 12

Mb/s

Inputs (optocoupled NPN or PNP)

Encoder, PS, PS Aux, 3 polarity insensitive optocoupled inputs

Outputs (optocoupled)

6 optocoupled outputs, 3 relay control inputs

USER INTERFACE
LCD Display

4 lines by 20 characters LCD

Keypad 6

keys

LED indicators

Power ON
TX data
RX data
Ethernet

PS
PS Aux
TACH
Networks

Controller
Scanners


SOFTWARE FEATURES
Configuration modes

Genius™ utility program

Parameter storage

Non-volatile extractable FLASH card


ENVIRONMENTAL FEATURES
Operating temperature

0° to +50 °C (+32° to +122 °F)

Storage temperature

-20° to +70 °C (-4° to +158 °F)

Humidity

90% non condensing

Vibration resistance

IEC 68-2-6 test FC

14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;

2 g @ 70-200 Hz; 2 hours on each axis

Shock resistance

IEC 68-2-27 test EA

30 g; 11 ms;

3 shocks on each axis

Protection class

IP64*

PHYSICAL FEATURES
Mechanical dimensions

320 x 250 x 90 mm (12.6 x 9.84 x 3.54 in)

Weight

3.3 kg. (7.26 lb)

*with Harting RJ Industrial push pull Ethernet connector.